Internal Runtime error

Internal Runtime error

Error appeared on a BP3800MK2 with Galil 4040 and OS Win 7 32 bit when BPwin has been updated from V5.55 to V7.0.x




 "Internal Runtime Error" message are generic, and do not mean anything other than BPWin and Windows have a conflict. 

Reinstalling visual studio redistributable version vcredist2015_x86.exe fixed this issue. This file can be found in C:\Program Files (x86)\BP Microsystems\BPWin 7.0.4\Drivers\




    • Related Articles

    • BPWin Error Codes

      BPWin includes a variety of error messages to help debug problems with the software and hardware, the following table lists these error message to aid in fault finding. Programming Errors Error 3: Cannot reset hardware. ​ The software cannot ...
    • TS1500 - Tray Stacker Air Pressure Error

      Issue BPWin software displays a message to indicate that there is no air pressure to the tray stacker. A physical check of the air input regulators, air lines and connections shows that there is good air pressure going to Tray stacker. The error ...
    • X Axis Timeout Error on 4000 Series Windows Autohandler

      The X-axis is the long, left/right axis. Also called the upper axis. (Note: For old DOS systems, this would be the "Y" axis)  The time-out error message is received because the X motor drive system did not get to the encoder position within a certain ...
    • X Axis Timeout Error on 4000 Series Windows Autohandler

      The X-axis is the long, left/right axis. Also called the upper axis. (Note: For old DOS systems, this would be the "Y" axis)  The time-out error message is received because the X motor drive system did not get to the encoder position within a certain ...
    • Y Axis Timeout Error on 4000 Series Windows Autohandler

      The Y-axis is the short, front/back axis. Also called the lower axis. (Note: For old DOS systems, this would be the "X" axis)  The time-out error message is received because the Y motor drive system did not get to the commanded encoder position ...