Programmer DIP Switch Settings
When using older versions of software and hardware, care must be taken to ensure that the DIP Switches (SW1) on the programming site motherboard are set so as not cause conflicts with duplicated settings.
The following image shows the DIP switch SW1.
The ON position (up) is binary 0, the OFF position (down) is binary 1

The following table shows the correct DIP switch setting depending on the site number that is being set up.
Switch Number Position | Site Number |
8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
1 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
1 |
2 |
0 |
0 |
0 |
0 |
0 |
0 |
1 |
0 |
3 |
0 |
0 |
0 |
0 |
0 |
0 |
1 |
1 |
4 |
0 |
0 |
0 |
0 |
0 |
1 |
0 |
0 |
5 |
0 |
0 |
0 |
0 |
0 |
1 |
0 |
1 |
6 |
0 |
0 |
0 |
0 |
0 |
1 |
1 |
0 |
7 |
0 |
0 |
0 |
0 |
0 |
1 |
1 |
1 |
8 |
0 |
0 |
0 |
0 |
1 |
0 |
0 |
0 |
9 |
0 |
0 |
0 |
0 |
1 |
0 |
0 |
1 |
10 |
0 |
0 |
0 |
0 |
1 |
0 |
1 |
0 |
11 |
Related Articles
Adjusting Programmer Power Supplies
All BPM manual and automated programmers rely on the use of a single power supply, per site, to power the site up. From time to time, it maybe necessary to adjust the PSU supply voltages, specifically if BPWin diagnostics fails or a voltage rail is ...
TM50 Temperature Controller Settings
Omron E5GN Temperature Controller The Omron E5GN Temperature Controller is used to monitor and maintain a target temperature range for the sealing shoes of the heat sealer. The heat sealer is equipped with two controllers, which control the two ...
All Parallel Port Programmer Support Withdrawn
With Immediate Effect. BPM Microsystems announced in 2012 that they would no longer repair or calibrate any programmers with parallel ports, ahead of their End Of Life announcement. Please see these links: ...
In the DOS version, the configuration settings were saved to a file. Where did they go
With the introduction of the BPWin software, the configuration settings are no longer saved to a file. These settings are now being saved in the Windows Registry and are not deleted upon being uninstalled. This allows the user to continue to use ...
What is the best way to remove other USB devices connected to the same hub as the programmer
When removing other USB devices (for example, Flash Drives) connected to the PC while a USB programmer is actively engaged in an operation, use the "Safely Remove Hardware" icon in the Windows system tray first to avoid potential communication ...