TS1500 - Tray Stacker Air Pressure Error

TS1500 - Tray Stacker Air Pressure Error

Issue

BPWin software displays a message to indicate that there is no air pressure to the tray stacker.
A physical check of the air input regulators, air lines and connections shows that there is good air pressure going to Tray stacker.

The error message cannot be cleared and the tray stacker can't cycle trays with the software.

Resolution

The TS1500 Tray Stacker unit has an internal pressure sensor to indicate if compressed air is connected or not.
If the main system air pressure is enough, then the air pressure sensor might be set too high or is faulty. 

To adjust the pressure sensor, remove the Left Lower Panel. This will involve removing the Left Side Cover.
The pressure sensor is mounted on the Pneumatic Air Panel after the main air input supply’s “Y” connection and is visible in the attached images.

Feed a long flat head screw driver through the small hole in the base plate under the sensor and adjust the screw at the pressure sensor’s base. If your screw driver is not long enough, unbolt the pressure sensor while maintaining the air connection. Re-bolt if after you are done if needed.

Turn the dial full counterclockwise. Then turn it ¼ turn clockwise. If the correct air pressure is connected and power is on to the Tray Stacker, the sensor’s indicator red light will turn on. Do not try to exactly set the sensor based on the light to the pressure supplied as that might create problems.

 Please also refer to the TS1500 User Manual provided with the system or search the Help File in BPWin.

 

    • Related Articles

    • TS1500 Wing Finger Height Adjustment

      A Setup and Calibration Tool (FTRAY-CALTOOL) may be used to check the height of the Wing Fingers. Place the tool on the Top Plate as shown in the image. Make sure that the tool is not sitting on the belt. The top surface of the thin portion of the ...
    • BPWin Error Codes

      BPWin includes a variety of error messages to help debug problems with the software and hardware, the following table lists these error message to aid in fault finding. Programming Errors Error 3: Cannot reset hardware. ​ The software cannot ...
    • 3X Shuttle Auto Retracts After Ejecting Tray

      When a tray of devices has been programmed, the tray shuttle will automatically eject the tray. In the event of hardware failure, the ejected tray can be taken straight back inside the autohandler. The shuttle needs an adjustment for one of the ...
    • Internal Runtime error

      Error appeared on a BP3800MK2 with Galil 4040 and OS Win 7 32 bit when BPwin has been updated from V5.55 to V7.0.x  "Internal Runtime Error" message are generic, and do not mean anything other than BPWin and Windows have a conflict.  ...
    • Automated Socket Modules and Pressure Plates

      For a full list of Automated Socket Modules and the Pressure Plates required to be used on automated handlers, then please view the list here.