Cyber Status 5, Link Error

Cyber Status 5, Link Error

Summary

Handler will not initialise. Log file shows Cyber Status 5, Link Error.

Details

Conditions: Handler will not initialise. There is no motion. Log file shows Cyber Status 5.
The Cyberoptics error table states "Link Fail (Sensor Data Error)" A data error has occurred on the communications link from the Camera to the SCM board. This error can be caused by electrical noise or a loose (broken) connection to the Camera. Refit all COAX cable connections.
Check the red LEDs on the SCM board. 
If the LED closest to the green LED is lit, use a DVM to ohm out the cable, checking for crosstalk and grounding. Parts to replace as necessary:
CCYBSCMBDCONFIG, SCM board
CCYBSENHD, Camera
CCYBCAB, COAX Cable, old style, one piece.
New style are the upper and lower Gore trackless sections. 

Date Created
2014-12-03 14:07:56
Date Updated
2014-12-03 14:07:56


    • Related Articles

    • No communication with Cyberoptics system

      Summary Handler cannot initialize because of lost communication with Cyberoptics system DetailsNot to be confused with Cyber Status 5 (no communication between the SCM board and the Camera) Typical log file snippet: 2010-10-18 13:23:18 -0800  Cyber ...
    • Cyber Optics Error Codes

      The following is a list of common error codes which are either reported by BPWin or appear in the BlackBox files. Error code 5 According to the Cyber documentation, this error code states that communication from the Cyber interface controller to the ...
    • Code 98 Error

      According to the Cyber documentation, this error code states verbatim: Angle limit exceeded. The angle exceeded specified angle limit before a minimum was detected. Check pre-rotation, angle limit, and/or component height. Basically, when a device ...
    • BPWin Error Codes

      BPWin includes a variety of error messages to help debug problems with the software and hardware, the following table lists these error message to aid in fault finding. Programming Errors Error 3: Cannot reset hardware. ​ The software cannot ...
    • CyberOptics Image Quality Test

      CyberOptics Camera Image Quality Test This test should be used to ensure that the CyberOptics Laser Align Camera is functioning properly and clear of debris. The test is automatically run at initialization and at the beginning of the job. Various ...