How to change the IP address on FR Cube

How to change the IP address on FR Cube

In this mini guide, I go through how you can change the IP address on a FlashRunner Cube, to enable communication through the Ethernet port.

Firstly, you have to know the IP address of the programmer you wish to access.
If you do not know the IP address, then you can use RS-232 comms between your PC and the Cube, so that you can communicate with the Cube and change its IP address via the FR Cube software.  If you do not have RS-232 port on your PC, then there free IP Address Sniffer utilities available online.

Connect your PC to the programmer using LAN connection and make sure the programmer is powered up.

Make sure that the IP of your PC is on the same range as the programmer.
For example, the default IP address of a Cube is 192.168.1.10 so your PC should be set to 192.168.1.XXX.  The IP of your PC can be changed in the Network Connections in Windows, right click on the relevant Local Area Connection and select properties.  Select Internet Protocol Version 4 from the connections types.  In the TCP/IPv4 Properties window, select the Use the following IP address and set the IP address as required.  Click OK, then OK to save the information.

Use the FR Cube software and make sure that the IP of your programmer is set correctly in the Model Selection.

In the FR Cube terminal, click SET IP button. 
This will display the code to change IP and display the default, even if it is not set to that address.
This command should be similar to this: " and update the IP address]">#sys -o set -p ip -v 192.168.1.11
Just change 192.168.1.11 to whatever you wish to change the programmer to.

Hit enter and you should get a result like this:

#sys -o set -p ip -v 192.168.1.11
192.168.1.11
>
The ">" indicates a pass and the IP address should be what you set it too. NOW CYCLE PROGRAMMER POWER!!!!!
If you do not, then the setting are not stored. Now, make sure you update the PC IP address so it is still on the same range as the new IP address.
Update the IP in the Model Selection.

You are now ready to continue.
    • Related Articles

    • Critical Change Summary

      Device Changed BPWin Version Date Reason NEC uPD70F3425GJ(A)-GAE-QS-AX 5.30.0 16/01/2013 Updated codes to resolve over current error. Micron N2M400FDB311A3CE Micron N2M400FDB311A3CF 5.29.0 27/12/2012 Algorithm is updated to add Extended_CSD ...
    • SMH Warranty

      The warranty periods for SMH Technologies range of products is as follows. 1 Year Warranty INDART-ONE FR03 MPX160A INDART-STX/D  3 Year Warranty  FR Cube FR01EXP01 FR01LAN FR01ENG FR04A04 FR04A08 FR04A16 FR01AT0 FR3070A FR01M01 FR02XXX   
    • TS1500 - USB Communication Problem

      If you are experiencing issues with obtaining communication via USB to your TS1500 tray Stacker, then please read the following information. You need to ensure that the driver is correct and that you have only one instance of DUB-E100 listed in ...
    • TS1500 Ethernet Adapter, removal and installation of the correct driver

      Summary Instructions for replacing the TS1500 Ethernet Adapter (p/n: CUSBNIC-2) are listed below. Details Unplug the stacker USB cable at the stacker. Power the entire Automated Programming System down and remove the stackers' left side upper and ...
    • GDPR - Adaptsys Support Centre Policy.

      The GDPR is here. The European Union has taken a monumental step in protecting the fundamental right to privacy for every EU resident with the General Data Protection Regulation (GDPR) which came into effective May 25, 2018. Simply put, EU residents ...