Vision Component Error

Vision Component Error

BPM have recently added new features in BPWin, starting from 5.40, to support the new 3800MK2 that uses both upward and downward vision.

When installing new versions of software, it appears that as default, BPWin enables a new hardware function check that does not exist on other handlers.

The Problem
Are you seeing the following error message?

vision-component-fail


The Solution
To rectify the problem, close BPWin, then open the registry editor and navigate to:

32BIT: HKEY_LOCAL_MACHINE>SOFTWARE>BPM Microsystems>BPWin>AutoHandler>Components

64BIT: HKEY_LOCAL_MACHINE>SOFTWARE>Wow6432Node>BPM Microsystems>BPWin>AutoHandler>Components

In the right window, you will see UseUpwardDownwardVisionComponentsCheck the DWORD.
The following screenshot shows the DEFAULT value after I installed 5.44.1.

UseUpwardDownwardVision

If it is set to 1, change it to 0 then close the registry editor and start BPWin which will now initialize correctly.

This key is used to enable/disable the upward camera, so if it is set to 1 BPWin is expecting to communicate with it.  This should be set to 0 for all 4x/3x types unless it has an upward camera.


    • Related Articles

    • How can i save vision system images?

      TM50 Vision Inspection Images can be saved either: To USB memory stick, attached to the USB port on the monitor. Via FTP. NOTE: FTP server configuration is required. Contact us for further information.
    • Does the vision system save any data?

      Our TM50 Vision Inspection System does, as standard, save all NG (Not Good) images to the cameras internal memory. These images can be accessed via the Sensor Image History, found in the Sensor Setup Menu on the Monitor. Under Logging Settings, it is ...
    • Cyber Optics Error Codes

      The following is a list of common error codes which are either reported by BPWin or appear in the BlackBox files. Error code 5 According to the Cyber documentation, this error code states that communication from the Cyber interface controller to the ...
    • Code 98 Error

      According to the Cyber documentation, this error code states verbatim: Angle limit exceeded. The angle exceeded specified angle limit before a minimum was detected. Check pre-rotation, angle limit, and/or component height. Basically, when a device ...
    • 3800MK2 No Downward Vision Image

      The 3800MK2 uses an upward and downward vision camera system for aligning devices. If you find that you have no downward camera Image then check the following points. Do you have Power and Activity LEDs on the downward camera? If Yes then we know ...