There are a variety of different programming sites available on BPM Microsystems handlers, each have different stepper motors, T-posts and power supplies.
This guide serves as a way to help identify the site technology that you have and the associated parts to aid in ordering spare parts.
Site Technologies and Spares
Please note that all 6th and 7th generation sites, such as 3600 or 4600 are no longer supported by BPM and should be upgrade
to X610 type sites.
Site Type
| Part
| Part Number
|
---|
3610/4610
| SITE
| FX610-240SITE
|
3610/4610
| STEPPER
| W4100STEPRPLC
|
3610/4610
| T POST
| D02959AD
|
3610/4610
| T POST TALL
| D02837AD
|
3610S/4610S
| SITE
| FX610-240-2-STE
|
3610S/4610S
| STEPPER
| D05136AD
|
3610S/4610S
| T POST
| D02959AD
|
3610S/4610S
| T POST TALL
| D02837AD
|
3710/4710
| SITE
| FX710-240SITE
|
3710/4710
| STEPPER
| W4100STEPRPLC
|
3710/4710
| T POST
| D02959AD
|
3710/4710
| T POST TALL
| D02837AD
|
3710/4710
| PSU
| CPWS082.2NFYCAP
|
3710S/4710S
| SITE
| FX710-240-2-STE
|
3710S/4710S
| STEPPER
| D05136AD
|
3610S/4610S
| T POST
| D04661AD
|
3710S/4710S
| T POST TALL
| D04652AD
|
3710S/4710S
| PSU
| CPWS082.2NFYCAP
|
3000FS
| SITE
| FX800F-SITE
|
3000FS
| STEPPER
| D05135AD
|
3000FS
| T POST
| WGEN2TPOSTKIT
|
3000FS
| PSU
| LPWSEXT24V
|
3800/4800
| SITE 16GB
| FX800-SITE
|
3800/4800
| SITE 326GB
| FX800-SITE-32
|
3800/4800
| SITE 64GB
| FX800-SITE-64
|
3800/4800
| STEPPER
| D05135AD
|
3800/4800
| T POST
| WGEN2TPOSTKIT
|
3800/4800
| 3800 PSU
| LPWSEXT24V
|
3800/4800
| 4800 PSU
| LPWS24V01
|
Notes:
D04664AD is obsolete and now uses D05136AD.
D04473AD is now obsolete and now uses D05135AD.
D04500AD is now obsolete and now uses WGEN2TPOSTKIT.
T Post Selection
Programming sites use T-posts that are threaded in to the stepper motors, used to open and close the sockets to allow devices to placed for programming.
There are various T Post types used and correct selection is based on the automated programming site style and the height of the socket module in use. When choosing a device to program in BPWin, there will be information to explain which socket modules can be used and the T-post required for any given socket module.
Refer to the examples shown below to further assist in choosing the correct T-post or if you need to order replacements.
Programming Site Style A (example: 4600) and Style B (example: 4610) are compatible with both D02959AD “Normal” T-post or D02837AD “Tall” T-post.
STYLE A
| STYLE B
|
---|
|
|
|
|
D02959AD "Normal" and D02837AD "Tall" T-Posts
|
NOTE: Style A, X600 type sites are obsolete and should be upgraded to X610.
Programming Site Style C (example: 4710S) is compatible with D04661AD “Normal” T-post or D04652AD “Tall” T-post.
STYLE C
|
---|
|
|
|
D04661AD "Normal" and D04652AD "Tall" T-Posts
|
Programming Site Style D (example: 4800) is compatible with WGEN2TPOSTKIT only.
STYLE D
|
---|
|
|
WGEN2TPOSTKIT
|
Summary Table
Site Style
| "Normal" T-post
| "Tall" T-post
|
---|
A
| D02959AD
| D02837AD
|
B
| D02959AD
| D02837AD
|
C
| D04661AD
| D04652AD
|
D
| WGEN2TPOSTKIT
| NA
|
Each T Post is fitted with ball plungers, which are used to unsure secure the fitting of the pressure plates.
These plungers are consumable items and can wear down.
Replacement parts can be ordered, using the following numbers.
CAIRPLU02 is the white tip plunger
CAIRPLU03 is the red tip plunger
If you are still unsure as to which T Post you should be using with your programming site, then please either call your local support engineer or submit a support request for further information.
Related Articles
Is programming affected by lead-free devices?
BPM Microsystems has investigated what impact lead free devices would have on the programming process. The main focus of the investigation was to see if lead free leads would have a negative effect on the electrical contact between the device leads ...
BPM Part Number Description Summary
Summary Description of Products, Programming Site Technology and Socket Module part numbers. Details Products type 1xxx – single site engineering programmer (1710, 1610, 1410/240, 1410/84) 2xxx – multi-site production programmer (2710, 2710M, 2610) ...
X800 Valid Site Configurations
On 8th Generation programming sites, upto 4 sockets cards can be place per programming site. With automated handlers, we employ stepper motors to pull down pressure plates to open and close the sockets and each device algo had code to establish to ...
Reducing upload and broadcast times for ultra large data files on USB site Autohandlers.
Having received complaints about the lengthy upload time and broadcast time for large data files, BPM have discovered that the ports that the site USB cables are connected to can makes a big difference in process speed. Refer to the attachment for ...
X300 Site Cooling
The fans are activated by thermistors connected from the analog board heat sink to J9 and J10 on the power board. They will only come on if the site gets above a certain temp the exact temp has not yet been confirmed but about 140 ambient degrees F, ...